Product Specs
Generator Set Specifications
- Standby Rating
- 2500 kVA
- Prime Power Rating
- 2275 kVA
- Emissions/Fuel Strategy
- Low Fuel, Low Emissions
- Voltage
- 380 to 415 Volts
- Frequency
- 50 Hz
- Speed
- 1500 rpm
- Duty Cycle
- Standby, Mission Critical, Prime, Continuous
- Maximum Rating
- 2500 kVA
- Minimum Rating
- 2000 kVA
Engine Specifications
- Engine Model
- 3516B TA, V-16, 4-Stroke Water-Cooled Diesel
- Bore
- 6.69 in
- Stroke
- 8.46 in
- Displacement
- 4764.73 in
- Compression Ratio
- 15.5:1
- Aspiration
- TA
- Fuel System
- Electronic unit injection
- Governor Type
- Adem™3
Generator Set Dimensions
- Length - Maximum
- 247.3 in
- Width - Maximum
- 90 in
- Height - Maximum
- 98.2 in
- Dry Weight - Genset (maximum)
- 34250 lb
Standard Equipment
-
- Air Inlet System
-
- Air cleaner; single element canister type
-
- Control Panels
-
- 0 True RMS AC metering, 3-phase, +/-2% accuracy
- Accessory module data link
- Low oil pressure
- 1 Programmable relay outputs (Form C)
- Reverse power (kW) (32)
- Warning/shutdown with common LED indication of shutdowns for:
- Environmental sealed front face
- Programmable protective relaying functions:
- kW-hr (total)
- Auto/start/stop control
- Generator set packages include Caterpillar's voltage regulator (IVR). IVR includes reactive droop capability, 3-phase voltage sensing, KVAR/PF modes, RFI suppression, min/max exciter. Limiter and exciter diode monitor
- EMCP 4.2B
- 6 Customer programmable digital inputs
- Load histogram feature
- Emergency stop pushbutton
- Reverse reactive power (kVAr) (32RV)
- Customizable screens
- Failure to start (overcrank)
- kW (per phase, average & percent)
- Low coolant level
- PLC functionality
- Communications:
- kVAr-hr (total)
- Engine cycle crank
- Coolant temperature
- kVA (per phase, average & percent)
- Controls:
- High coolant temperature
- Generator phase sequence
- Digital indication for:
- Over/under frequency (81 o/u)
- Number of I/O varies on options selected
- Low coolant temperature
- Alarm acknowledge
- 1 Programmable digital outputs
- Amps (per phase & average)
- Cat connect
- Overspeed
- Engine cool-down timer
- Operating hours
- Oil pressure (psi, kPa or bar)
- RPM
- Power factor (per phase & average)
- Serial annunciator module data link
- 24 Volt DC operation
- Overcurrent (50/51)
- Generator mounted - rear facing
- Over/under voltage (27/59)
- 3 Analog inputs
- 4 Programmable relay outputs (Form A)
- Speed adjust
- Text alarm/event descriptions
- kVAr (per phase, average & percent)
- Customer data link (Modbus RTU)
- Frequency (Hz)
- Volts (L-L & L-N)
- DC volts
- Lamp test
-
- Cooling System
-
- Certified standard PGS provided
-
- Exhaust System
-
- Flanged faced outlet(s)
- Dry exhaust manifold
-
- Fuel System
-
- Fuel cooler; not included with packages without radiator
- Flexible fuel lines - shipped loose
- Secondary fuel filters
- Fuel priming pump
-
- General
-
- Flywheel and flywheel housing - SAE No. 00
- SAE standard rotation
- Caterpillar yellow with high gloss black rails and radiator
- Right hand servicing
-
- Generator And Attachments
-
- Low voltage:
- Busbar connections, right side extension box, bottom cable entry
- Class H insulation, Class F temperature rise at 40C ambient (105C prime/130C standby)
- NEMA standard hole pattern
- Internal excitation (IE)
- Random wound
- Anti-condensation space heater
- Winding temperature detectors
- Form wound
- 6 Leads
- High voltage:
- Medium voltage:
- 3 Phase brushless, Salient pole
- Permanent magnet excitation (PMG)
- NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime/150C standby)
- Busbar connections, top center mounted, top cable entry
-
- Governing System
-
- ADEM A3
-
- Literature
-
- Parts book
-
- Lubrication System
-
- Oil drain lines and valve
- Fumes disposal
- Oil filter, filler and dipstick
- Lubricating oil
- Gear type lube oil pump
- Integral lube oil cool
-
- Mounting System
-
- Rails - Engine/generator/radiator mounting
- Rubber anti-vibration mounts - shipped loose
- Anti-vibration mounts (shipped loose)
-
- Starting System
-
- Battery and battery rack w/cables
- 24 Volt electric starting motor
- 45 Amp Charging alternator
- Battery disconnect switch
Attachments
-
- Control System
-
- EMCP 4.4
- Local annunciator module: [ ] NFPA 110 [ ] Custom
-
- Engine Options
-
- Starting aids: 220V 50 Hz Jacket water heater
- Batteries: [ ] Standard (1400 CCA) [ ] Heavy Duty (2800 CCA)
- Starting motors: [ ] Standard [ ] Heavy duty
- Air cleaner: [ ] Single element air cleaners [ ] Dual element air cleaners [ ] Heavy duty air cleaners
- Muffler: [ ] Industrial Grade
- Battery charger: [ ] 10A [ ] 20A [ ] 35A
-
- Air Inlet System
-
- Single element filter
- Dual element air cleaner
-
- Cooling System
-
- Coolant
- Standard ambient ATAAC radiators
- Water level switch gauges
- Standard ambient radiators
- Optional installed ATAAC radiators
- Optional installed radiators
-
- Crankcase System
-
- Ventilation system
- No explosion relief valves
- Explosion relief valves
-
- Alternators
-
- Temperature rise (over 40�C ambient): [ ] 150�C [ ] 125�C [ ] 105�C [ ] 80�C
-
- Power Termination
-
- Circuit breaker rating: [ ] 2000A [ ] 2500A [ ] 3200A [ ] 4000A
- Power Termination: Busbar, Circuit breaker
- Circuit breaker trip unit: [ ] LSI [ ] LSIG [ ] LSIG-P
-
- Exhaust System
-
- Y Adapters
- Tier 4 clean emissions module
- Clean emission parts
- Exhaust offset
- Elbows
- Tier 4 clean emission MOD Kits
- Flexible fittings
- Tier 4 dosing cabinet
- Mufflers
- Flanges
- Flange and exhaust expanders
-
- Fuel System
-
- Fuel priming pumps (Tier 4) - Manual or electric
- Primary fuel filter
-
- Extended Service Contract (esc)
-
- Extended Service Contract (ESC): [ ] 2 Year [ ] 3 Year [ ] 5 Year
-
- General
-
- US aid emblem
- Special paint (Colors other than Caterpillar yellow or high performance paints)
-
- Generators And Attachments
-
- Generator conversion
- Space heater
- Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, PM, No. of Leads = 6, Pitch = .6667: 1600 and 1800 Frames
- Differential current transformers (DCT) 8.7 kV and 15 kV classes
- Thermostat for space heater
- Alternator air cleaner
- Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame
-
- Instrumentation
-
- Pyrometer and Thermocouples
-
- Lubrication System
-
- Prelube pumps
- Lube oil in standard sump
- Oil level regulator
-
- Mounting System
-
- IBC vibration isolators
- Puck style low efficiency isolators
- Spring type vibration isolators
-
- Power Connections
-
- Left side power connections
- Rear power connections
- Ground cables between generator and terminal box
- 2700 Frame, four lead, four terminal
- Neutral ground connections
- Low voltage Circuit breakers
- Center post busbars
- Right side power connections
-
- Special Tests / Reports
-
- Torsional vibration analysis reports
- PGS Test report @ 0.8 power factor
- Standard engine test charge
- Generator set fuel consumption test
- OSHPD Certification
- PGS Test report @ 1.0 power factor
- Generator test report
- Fuel consumption test
- IBC Certification
- Canadian Standards Association certification
-
- Starting And Charging
-
- Jacket water heaters
- Electric starting motors
- Starter cover
- Air pressure regulator
- Engine barring device
- Air starting motors
- 24 Volt battery set - Dry
- 10, 20, 35 and 50 Amp Battery chargers
-
- Extended Service Coverage
-
- Platinum, Gold and Silver coverage